Automatic reclosing power protector
When the line returns to normal, the protector can automatically restore power supply. The overvoltage cut-off value, undervoltage cut-off value, overcurrent protection value, leakage protection value, etc. of this product can be set by oneself, and the corresponding parameters can be adjusted according to the local actual situation.
Suitable for electrical equipment ···
Product Introduction
The automatic reclosing protector is suitable for AC 50HZ and rated 220V power lines. When overvoltage, undervoltage, or overcurrent faults occur in the line, this product can instantly cut off the power supply to avoid unnecessary damage to electrical equipment.When the line returns to normal, the protector can automatically restore power supply. The overvoltage cut-off value, undervoltage cut-off value, overcurrent protection value, leakage protection value, etc. of this product can be set by oneself, and the corresponding parameters can be adjusted according to the local actual situation.Suitable for electrical equipment in various environments, such as homes, schools, enterprises, municipal engineering, streetlights, farms, rental houses, water pumps, underfloor heating, water heaters, etc.
PRODUCT FUNCTION
1. This product has an LCD backlight display, which displays real-time parameters such as grid voltage, current, leakage, and electricity. The product uses a high-precision metering chip specifically designed for State Grid Corporation of China, with 24 bit ADC numerical sampling accuracy.
2. The on-site setting protection functions include overvoltage, undervoltage, overcurrent, leakage, delay, etc. The battery can be accumulated and reset to zero. It also has the function of one click reset of factory settings in the setting menu.
3. This product does not support automatic closing function after leakage protection. When the product experiences leakage protection disconnection (screen displays OFF), please immediately check and eliminate the leakage fault of the circuit or equipment, and then manually close it before normal use.
4. Short press the setting button on the product to quickly view the setting parameters, and long press the setting button for three seconds to enter the setting program.
Main parameters and technical performance
| product name | Automatic reclosing power protector |
| Number of product poles | 1P+N |
| rated operational voltage | AC220V |
| rated working current | 1-63A |
| Rated working frequency | 50Hz/60Hz |
| Inductive | 6KW (motor type) |
| Resistive load | 13KW (electric lighting) |
| Power consumption | <2W |
| Overvoltage action cut-off value | 150V-300V adjustable (default 270V) |
| Reset value after overvoltage protection | When it is less than the overvoltage setting value of 15V, start recovery |
| Undervoltage action cut-off value | 80V-210V adjustable (default 170V) |
| Reset value after undervoltage protection | When the voltage exceeds the undervoltage setting value by 15V, initiate recovery |
| Range of overcurrent protection values | 1A-63A adjustable (default 63A) |
| Range of leakage protection values | Adjustable from 10mA to 100mA (default OFF) |
| Power on and reset delay time | 1s-300s adjustable (default 5s) |
| Electrical and mechanical lifespan | >105 |
| Installation method | Standard rail installation |
operational condition
1. Surrounding air temperature
Operating temperature: -25 ℃~+75 ℃; The average value within 24 hours shall not exceed+35 ℃.
2. Altitude
The altitude of the installation site shall not exceed 2000 meters.
3. Atmospheric conditions
a. When the ambient air temperature is+35 ℃, the relative humidity of the air does not exceed 50%, allowing for higher relative humidity at lower temperatures.
b. When the monthly average lowest temperature of the wettest month is+20 ℃, the monthly average relative The humidity should not exceed 90%, taking into account the occurrence of temperature changes in the product Surface condensation.
4. Pollution level
The pollution level used for the protector is level 3.
5. Installation category
Installation categories are II and III.
6. Installation conditions
a. The protector can be installed vertically or horizontally inside the cabinet, and special requirements require special ordering.
b. It should be installed in a medium without explosive hazards, and there should be no gas or conductive dust in the medium that can corrode metals and damage insulation.
c. It should be installed in a place without rain or snow invasion.
Wiring diagram

Product size

- ← Previous: No More
- No More :Next →
Yueqing Yijin Electronics Co.,Ltd