YJC-120/25/63 household AC contactor (hereinafter referred to as the contactor) is mainly suitable for use in power systems with AC 50Hz (or 60Hz) rated working voltage of 230V. Under the AC-7a usage category, it is used as a remote switch and main circuit control in circuits with rated working voltage up to 230V and rated working current of 63A. This product is mainly used for controlling low inductance loads and household motor loads in household appliances and similar applications.
This product complies with GB17885 and IEC1095 standards.

Scope of use

YJC-120/25/63 household AC contactor (hereinafter referred to as the contactor) is mainly suitable for use in power systems with AC 50Hz (or 60Hz) rated working voltage of 230V. Under the AC-7a usage category, it is used as a remote switch and main circuit control in circuits with rated working voltage up to 230V and rated working current of 63A. This product is mainly used for controlling low inductance loads and household motor loads in household appliances and similar applications.

This product complies with GB17885 and IEC1095 standards.

Model meaning and its classification

YJC1-63 1P Modular AC Contactor


Note: Conventional products are normally open, and normally closed products can be customized.

Normal working conditions and installation conditions

The surrounding air humidity is:- 5 ℃ -+40 ℃, with an average value not exceeding+35 ℃ within 24 hours

The altitude shall not exceed 2000m.

The relative humidity of the air at the installation site under atmospheric conditions should not exceed 50% at a maximum temperature of+40 ℃. Higher relative humidity is allowed at lower temperatures, and the average minimum temperature in the wettest month should not exceed+25 ℃. The average maximum relative humidity for that month should not exceed 90%, taking into account condensation on the product surface due to temperature changes.

Pollution level: Pollution level 2

Installation category: for installation category III

Installation method: The TH35-7.5 type installation rail with a "top cap" cross-section is used.

Technical Parameter

The rated insulation voltage, agreed heating current, usage category, and corresponding rated working current and control function of the contactor are shown in Table 1

Use category codesRated insulation voltage (V)Rated working voltage (V)Agreed heating current (A)Rated working current (V)Control power (KW)
AC1、AC7aAC7bfive hundred230Vsixty-three63/2513/3.8
AC1、AC7aAC7bfive hundred230Vforty40/158.4/2.4
AC1、AC7aAC7bfive hundred230Vthirty-two32/126.5/1.9
AC1、AC7aAC7bfive hundred230Vtwenty-five25/8.55.4/1.5
AC1、AC7aAC7bfive hundred230Vtwenty20/474/1.2

Action (operation) conditions

Apply the rated control power supply voltage Us to the contactor suction coil within the range of -5 ℃ -+40 ℃ in the surrounding air temperature, so that it heats up to a stable state. The contactor can reliably close at any voltage within the range of (80% -110%) Us, and its release voltage is neither higher than 75% Us nor lower than 20% Us.

The connection and disconnection capabilities are shown in Table 2

Utilization categoryConnection and disconnection (on-off) conditionsPower on time (S)Interval time (S)Number of operation cycles
le/teUr/UeCosφ
AC-1、AC-7aone point fiveone point zero fivezero point eightzero point zero fivetenfifty
AC-7beightone point zero fivezero point four fivezero point zero fivetenfifty

The agreed upon operational performance is shown in Table 3

Utilization categoryConnection conditionsBreaking conditionsPower on time (S)Interval time (S)Number of operation cycles
I/te U/Ue CosφIc/te Ur/Ue Cosφ
AC-1oneone point zero fivezero point eightoneone point zero fivezero point eightzero point zero fivetensix thousand
AC-7aoneone point zero fivezero point eightoneone point zero fivezero point eightzero point zero fivetenthirty thousand
AC-7bsixonezero point four fiveonezero point one sevenzero point four fivezero point zero fivetenthirty thousand

Mechanical lifespan: The mechanical lifespan of the contactor shall not be less than 1 million cycles

Electrical lifespan: The electrical lifespan of the contactor shall not be less than 100000 times